
Purchase Finder Surge Protection Device in Vadodara: Genuine Products for Industrial Panels
Looking to purchase a Finder surge protection device in Vadodara for an electrical panel, factory expansion or maintenance project? Ahmedabad Electrical Corporation supplies genuine Finder products through its associated supply network, including AIM Innovations, serving panel builders, OEMs, contractors and industrial purchasers across Gujarat and India.
Our focus is straightforward: identify the correct product, confirm availability and provide a clear quotation. Selected products are available from ready stock, while bulk orders and special references receive a separate supply commitment.
For buyers in Makarpura, Savli, Nandesari and nearby industrial areas, sending the complete specification helps prevent incorrect purchases and installation delays.
Why industrial panels need surge protection
Transient overvoltages can originate from lightning-related events or electrical switching. These brief disturbances can affect sensitive equipment, including PLCs, instrumentation, power supplies and communication devices.
A correctly selected surge protection device, or SPD, limits transient overvoltage as part of a coordinated protection system. Finder’s range includes products for power circuits and dedicated protection for Ethernet and other sensitive applications.
An SPD does not replace an MCB, MCCB, RCCB or effective earthing. Each serves a different function within the installation.
Finder 6P.14.8.320.1012: understand the featured product
The featured Finder 6P.14.8.320.1012 is described in its product sheet as a Type 1+2 SPD for three-phase AC systems with neutral, including suitable TT and TN-S arrangements.
Its documented features include:
- Three varistor modules and one encapsulated spark-gap module.
- Phase-to-neutral varistor protection and neutral-to-earth spark-gap protection.
- Replaceable protection modules.
- Visual healthy/replace indication.
- Optional remote status signalling.
- Mounting on a 35 mm DIN rail.
- Application at the LPZ 0–LPZ 1 boundary, subject to system design.
For this reference, confirm the latest datasheet, availability and supplied signalling arrangement before ordering. Use the manufacturer’s documentation for electrical ratings rather than relying on promotional artwork.
Type 1, Type 2 or Type 3: what should buyers specify?
The appropriate SPD depends on the installation’s lightning exposure, electrical system and equipment:
- Type 1: Intended for installations where lightning-current discharge capability is required.
- Type 2: Used for transient-overvoltage protection in distribution systems.
- Type 1+2: Combines the relevant protection capabilities in one device.
- Type 3: Provides coordinated protection close to sensitive equipment.
These devices must be selected and coordinated together where required. A compact point-of-use SPD should not automatically be substituted for protection required at the installation origin.
Check these details before requesting your quotation
“Three-phase surge protector required” is only the starting point. Send:
- Supply voltage and frequency.
- Earthing arrangement: TT, TN-S or another system.
- Required SPD type and installation location.
- Maximum continuous operating voltage, Uc.
- Required protection level, Up.
- Applicable discharge ratings, including Iimp, In or Imax.
- Upstream protective-device details and available fault current.
- Remote indication, replacement-module and quantity requirements.
Discharge-current ratings use different test waveforms, so the largest advertised kA figure is not necessarily the right purchasing criterion. Installation layout, conductor lengths and bonding also influence protection performance.
Have a qualified electrical professional verify the selection and installation against the exact product instructions.
Related Finder products and ordering references
For a consolidated panel BOM, consider these application-specific enquiries:
- 7P.68.9.060.0600: Finder SPD for Ethernet, PoE and data lines up to 250 MHz; verify compatibility with the network equipment.
- 7T.51.0.230.4360: Panel thermo-hygrostat for combined temperature and humidity control.
- 7T.81.0.000.2403: Heating-control thermostat with a normally closed contact and 0°C to +60°C setting range.
- 7T.81.0.000.2303: Ventilation-control thermostat with a normally open contact and 0°C to +60°C setting range.
These are complementary products for different functions, not interchangeable surge protectors. Availability and suitability should be confirmed individually.
Gujarat delivery coverage: major cities and smaller clusters
We welcome enquiries from GIDC estates and adjoining industrial areas:
- Vadodara: Makarpura, Savli, Nandesari, Ranoli, Waghodia, Por–Ramangamdi and Dabhoi.
- Ahmedabad: Sanand, Vatva, Naroda, Odhav, Kathwada, Dholka and Mandal.
- Gandhinagar–Mehsana: Chhatral, Kalol, Kadi, Dediyasan, Gozaria and Kukerwada.
- Bharuch: Ankleshwar, Panoli, Jhagadia, Dahej, Saykha, Palej and Jambusar.
- Surat: Sachin, Pandesara, Ichhapor, Katargam, Olpad and Bardoli.
- South Gujarat: Vapi, Sarigam, Umbergaon, Gundlav, Pardi, Navsari and Bilimora.
- Rajkot–Morbi: Aji, Bhaktinagar, Lodhika–Metoda, Kuvadva, Gondal and Rafaleshwar.
- Jamnagar–Surendranagar: Shanker Tekri, Dhrol, Wadhwan, Halvad, Chotila and Limbdi.
- Bhavnagar–Saurashtra: Chitra, Vartej, Sihor, Botad, Junagadh, Veraval, Porbandar and Amreli.
- Kutch: Gandhidham, Anjar, Bhuj, Mandvi, Mundra and Nakhatrana.
- Central–North Gujarat: Vithal Udyognagar, Nadiad, Halol, Godhra, Dahod, Himmatnagar, Modasa, Patan, Palanpur and Deesa.
Ready stock and fast nationwide supply
For confirmed available material, our delivery targets are 4–5 days within Gujarat and 5–6 days to major Indian metros, subject to order acceptance and transport availability.
Contact Ahmedabad Electrical Corporation with your part number, quantity and delivery PIN code. Request model-wise pricing, GST, freight, warranty terms and dispatch confirmation for your next Finder SPD order.
Keywords






